Dual-voltage lead-acid charging, LCD status display and a folding carry handle.
Current model specification checked against the supplied product information and instruction sheet. The summary keeps maximum output separate from the stated constant-current rating.
Current model specification
| Battery / output version | 12V / 24V |
|---|---|
| Battery chemistry | Compatible lead-acid batteries |
| Output current | 16A maximum at 12V / 8A maximum at 24V |
| Continuous-current rating | 8A constant current at 12V; 24V continuous rating to confirm |
| AC input | 100–240V AC, 50/60Hz |
| Recommended battery capacity | 12V: 7–200Ah; 24V: 7–100Ah |
| Functions | Three-stage charging, LCD status, fan cooling and repair mode. |
| Dimensions | Approx. 230 × 200 × 100mm |
| Net weight | Approx. 1.2kg |
Confirm before ordering
- 24V continuous-current rating
- Battery subtypes and intended charging duty for the exact order
- Destination-specific plug, labeling and compliance documents
- Any requested cable or packaging changes
Repair mode cannot guarantee recovery of a damaged or end-of-life battery. Current model information does not establish jump-starting, waterproof marine installation or long-term unattended maintenance.
Prepare a model-specific inquiry
Include the battery chemistry, nominal voltage and capacity, intended use, quantity, destination, AC plug, and any labeling or packaging requirements. Ask for the applicable manual and any destination-specific compliance documentation for the exact revision.
Public contact: info@power1986.com. Information checked 2026-11-04. Unconfirmed fields remain open.